Starsplas Green Environmental Protection High Quality CPE Raw Material for ABA WPC Waterproof Flooring

Starsplas Green offers CPE raw material for ABA WPC waterproof flooring. We are a high-quality, environmentally-friendly factory for all your flooring needs.
Request a Quote

PRODUCTS DETAILS

  • Overview
  • Product Usage
  • Product Description
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
SP-CPE
Transport Package
Ship Container
Specification
PVC
Trademark
StarsPlas
Origin
China
Production Capacity
10tons/Day

Product Description

Starsplas Green Environmental Protection High Quality CPE Raw Material for ABA WPC Waterproof Flooring
Starsplas Green Environmental Protection High Quality CPE Raw Material for ABA WPC Waterproof Flooring
Product Usage

It is an excellent modifier for PvC plastics, widely used in the modification of cables, electric wires, hoses, rubber fabrics, rubber and plastic products, sealing materials, PVC profiles, plates, pipes, ABS, etc.
 

Product Description

Physical Properties

Ingredient/Composition 
Information:

Pure substance

CAS No.:

63231-66-3

Hazard Class:

According to the Globally Harmonized System of 
Classification and Labeling of Chemicals (GHS) 
classification, this product is non-hazardous and not harmful to health or the 
environment.

Appearance and 
properties
:

white powder, non-toxic and tasteless, 
with excellent resistance to weathering, 
ozone, chemicals and aging, good oil resistance, 
flame retardancy and coloring properties.

pH value: 

N/A

Melting point(ºC): 

Not available

Boiling point(ºC): 

Not available

Relative density: 

1.22 g/mL at 25 ºC

Vapor density: 

N/A Saturated

Vapor pressure(kPa): 

N/A

Heat of combustion(kJ/mol): 

Not available

Critical temperature(ºC): 

Not available

Critical pressure(MPa): 

Not available

Octanol/water partition 
coefficient: 

Not available

Flash point(ºC): 

N/A

Flammability: 

Not available

Explosion hazard: 

No explosion hazard

 

Use: CPE can be used as PVC impact modifier and rubberized chlorinated polyethylene.

 

First Aid Measures

Skin contact: 

Rinse immediately and thoroughly with water and soap, seek medical advice.

Eye contact: 

Lift eyelids and flush with running water or saline. If discomfort occurs, 
seek medical attention.

Inhalation: 

Quickly remove from the scene to fresh air. Seek medical attention if you feel unwell.

Ingestion: 

Seek medical attention if you feel unwell.

 

Fire Fighting Measures

The substance or mixture is particularly dangerous: 

if exposed to fire, it will release: carbon monoxide, 
carbon dioxide, hydrogen chloride

Fire extinguishing methods:

Use carbon dioxide, fire extinguishing powder 
or water spray to extinguish the fire, if the fire is 
very large, use water spray If the fire is very large, 
please use water spray or Kang-sol foam liquid.

Firefighting precautions and measures: 

firefighters must wear air breathing apparatus, full-body fire 
and gas-proof clothing, in the Put out the fire upwind. 
If possible, 
move the container from the fire to the open area. 
Until the fire is extinguished

 

Emergency response to spills

Emergency action: 

Eliminate all ignition sources and evacuate all personnel from the side and 
upwind to a safe area. Recommended emergency response Personnel should 
wear positive pressure self-contained breathing apparatus and anti-toxic and 
anti-static clothing. All equipment used during operation should be Grounded. 
Do not touch or cross the spill. Cut off the source of the spill if possible. 
Prevent spills from entering water prevent spills from entering water, sewers, 
basements, or confined spaces. Small spills: Absorb with sand or other non-combustible materials. Collect. 
Use clean, non-sparking tools to collect absorbent material. 
Large spills: Construct dikes or dig pits to collect Capacity. 
Absorb large amounts of liquid with flying dust or lime powder. 
Cover with foam to reduce evaporation.

 

Operational disposal and storage

Handling precautions:

operate airtight and strengthen ventilation. Operators must be specially 
trained and strictly follow the operating procedures. It is recommended that 
operators wear self-absorbing filtered dust masks (and chemical safety glasses.) 
Keep away from fire and heat sources, and smoking is strictly prohibited in the 
workplace. Use explosion-proof ventilation systems and equipment. 
Avoid dust generation. Avoid contact with oxidizing agents. 
Avoid damage to packaging and containers. 
Equip with appropriate types and quantities of fire-fighting equipment and 
emergency equipment for spills. Empty containers may contain residual 
hazardous materials.

Storage precautions: 

Store in a cool, ventilated warehouse. Keep away from fire and heat sources. 
It should be stored separately from oxidizers and should not be mixed. 
The storage area should be equipped with spill response equipment 
and suitable shelter materials.

 

Exposure Control / Individual Protection

More information on 
technical system design:

Fume hoods used for hazardous chemicals should have 
a minimum hood opening air velocity of 100 ft/min during 
normal operation.

Control Parameters

Components with critical values that 
need to be monitored in the workplace: 

No requirement

Personal Protective Equipment

General protective and sanitary measures: 

When handling chemicals, general precautions should 
be followed. Keep away from food, drink and feed. 
Remove all contaminated or impregnated clothing 
immediately. Wash your hands at breaks and 
after work. Maintain an ergonomic work environment.

Oxygen supply equipment: 

Use a high concentration respiratory protection device.

Hand protection: 

Check that protective gloves are in order before each use. 
Choosing the right gloves depends not only on the 
material. It also depends on the quality of the material, 
and the quality varies from manufacturer to manufacturer.

Glove material: 

impermeable gloves

Eye protection: 

safety glasses

Body protection: 

Protective overalls

 

Waste disposal

Nature of waste: 

industrial solid waste, waste

Waste disposal method: 

Disposal by incineration is recommended.

Waste precautions: 

Refer to the relevant national and local regulations before disposal

 
Starsplas Green Environmental Protection High Quality CPE Raw Material for ABA WPC Waterproof Flooring

Shipping Information

Packing method:

 inner plastic bag, outer kraft paper bag or woven bag of composite packaging

Transportation precautions: 

The package should be complete when starting transportation, and the loading should be stable. Ensure no leakage, collapse, fall or damage during transportation. It is strictly forbidden to mix and transport with oxidizer and so on. During transportation, it should be protected from sun and rain and high temperature

 

Company Profile

 

Starsplas Green Environmental Protection High Quality CPE Raw Material for ABA WPC Waterproof Flooring

Certifications

Starsplas Green Environmental Protection High Quality CPE Raw Material for ABA WPC Waterproof Flooring

FAQ
Starsplas Green Environmental Protection High Quality CPE Raw Material for ABA WPC Waterproof Flooring

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours